Zippy P2G-5600V 2U Single

 

Features:

  • Output Wattage : 600W
  • Best Solution for: Server, Workstation, Storage System, IPC
  • Dimension:
    240.00 x 100.00 x 70.00 (mm)
    9.45 x 3.94 x 2.76 (inch)
Categories: , Tag:

Description

Specifications:

AC INPUT SPECIFICATION

  • VOLTAGE: 90 ~ 264VAC FULL RANGE
  • FREQUENCY : 47 ~ 63 HZ
  • INPUT CURRENT: 9A(RMS) FOR 115VAC, 4.0A(RMS) FOR 230 VAC
  • INRUSH CURRENT: 25A MAX. FOR 115 VAC, 50A MAX. FOR 230 VAC
  • POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% AT 115/230VAC, FULL LOAD

DC INPUT SPECIFICATION

OUTPUT VOLTAGE
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.(A)
MAX.(A)
LOAD
LINE
RIPPLE & NOISE
MAX.[P-P]
+5V
0.5
25
±5%
± 1%
60mV
+12V
0.5
46
±5%
± 1%
120mV
-12V
0
0.8
±5%
± 1%
120mV
+3.3V
0.5
25
±5%
±1%
60mV
+5VSB
0
3.5
±5%
± 1%
60mV
  • TEMPERATURE RANGE: OPERATING 0℃ — 50℃, STORAGE –20℃ — 80℃
  • HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
  • EFFICIENCY: 80~84% TYPICAL AT 115V, FULL LOAD
  • POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
  • OVER POWER PROTECTION
  • OVER VOLTAGE PROTECTION
  • OVER CURRENT PROTECTOIN
  • SHORT CIRCUIT PROTECTION
  • EMI: FCC CLASS B, CISPR22 CLASS B
  • SAFETY: TO MEET UL, CUL, TV, CCC
  • 3.3V / 5V / 12V REMOTE SENSING
  • COOLING: ONE 60mm DC FAN
  • DIMENSION: 240 (D) x 100 (W) x 70 (H) mm
  • MEET IEC-1000-3-2 CLASS D
  • *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.