Description
Specifications:
AC INPUT SPECIFICATION
- VOLTAGE: 90 ~ 264VAC FULL RANGE
- FREQUENCY : 47 ~ 63 Hz
- INPUT CURRENT: 9.0A @115V; 5 A @ 230 VAC
- INRUSH CURRENT: 35A @ 115V; 75A @230 VAC
DC INPUT SPECIFICATION
OUTPUT VOLTAGE | OUTPUT CURRENT | REGULATION | OUTPUT |
| MIN.(A) | MAX.(A) | LOAD | LINE | RIPPLE & NOISE
MAX.[P-P] |
+5V | 1 | 32 | ± 5% | ± 1% | 50mV |
+12V | 1 | 57 | ± 5% | ± 1% | 120mV |
-12V | 0 | 0.8 | ± 5% | ± 1% | 120mV |
+3.3V | 1 | 32 | ± 5% | ± 1% | 50mV |
+5VSB | 0.1 | 3.5 | ± 5% | ± 1% | 50mV |
Remarks:
* TOTAL OUTPUT OF +5V & +3.3V NOT EXCEED 190W
* TOTAL OUTPUT POWER NOT EXCEED 700W
|
- TEMPERATURE RANGE: OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 80℃
- HOLD UP TIME: DC OUTPUT 12V MUST BE MAINTAIN 16 ms IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
- EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD
- POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
- OVER POWER PROTECTION: 100~180%
- OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→13.3~14.3V
- SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB
- EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
- FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
- SAFETY: TO MEET UL, CUL, TUV, RFI/EMI STANDARDS
- REMOTE ON/OFF CONTROL
- COOLING: TWO 40mm DC FANS (MODULE)
- *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
|
|